Products

  • Integrated Low Range Turbidity Sensor With Display

    Integrated Low Range Turbidity Sensor With Display

    ★ Model No: BH-485-TU

    ★ A continuous reading turbidity meter designed for low range turbidity monitoring

    ★ EPA principle 90-degree scattering method, specially used for low-range turbidity monitoring;

    ★ The data is stable and reproducible

    ★ Simple cleaning and maintenance;

    ★ Protocol: Modbus RTU RS485 

    ★ Power Supply: DC24V(19-36V)

    ★ Application: surface water, tap water factory water, secondary water supply etc

  • Online Secondary Water Supply Turbidity Sensor

    Online Secondary Water Supply Turbidity Sensor

    ★ Model No: BH-485-ZD

    ★ A continuous reading turbidity meter designed for low range turbidity monitoring

    ★ The data is stable and reproducible

    ★ Easy to clean and maintain

    ★ Protocol: Modbus RTU RS485 

    ★ Power Supply: DC24V(19-36V)

    ★ Application: surface water, tap water factory water, secondary water supply etc

  • Digital Drinking Water Turbidity Sensor

    Digital Drinking Water Turbidity Sensor

    ★ Model No: BH-485-TB

    ★ High performance: indication accuracy 2%, minimum detection limit 0.015NTU

    ★ Maintenance-free: intelligent sewage control, no manual maintenance

    ★ Small size: especially suitable for system set to make

    ★ Protocol: Modbus RTU RS485 

    ★ Power Supply: DC24V(19-36V)

    ★ Application: surface water, tap water factory water, secondary water supply etc

  • Online Residual Chlorine Analyzer Used For Medical Wastewater

    Online Residual Chlorine Analyzer Used For Medical Wastewater

    ★ Model No: FLG-2058

    ★ Output: 4-20mA

    ★ Protocol: Modbus RTU RS485 

    ★ Measure Parameters: Residual Chlorine/Chlorine Dioxide,Temperature

    ★ Power Supply: AC220V

    ★ Features: Easy to install, high precision and small in size.

    ★ Application: Medical wastewater, industrial wastewater etc

  • Online Residual Chlorine Analyzer/Chlorine Dioxide Analyzer

    Online Residual Chlorine Analyzer/Chlorine Dioxide Analyzer

    ★ Model No: CL-2059B

    ★ Output: 4-20mA

    ★ Protocol: Modbus RTU RS485 

    ★ Measure Parameters: Residual Chlorine/Chlorine Dioxide,Temperature

    ★ Power Supply: AC220V

    ★ Features: Easy to install, high precision and small in size.

    ★ Application: Drinking water and water plants etc

  • Online Inductive Digital Acid Alkaline Concentration Sensor

    Online Inductive Digital Acid Alkaline Concentration Sensor

    ★ Model: DDG-GYG

    ★ Measure range:  HNO3: 0~25.00%; H2SO4: 0~25.00%; 

    HCL: 0~20.00%; NaOH: 0~15.00% ; 

    ★ Protocol: 4-20mA or RS485 signal output

    ★ Power Supply: DC12V-24V

    ★ Features: Strong anti-interference, High accuracy

    ★ Application: Chemical, Waste water, River water, Power plant

  • Digital Inductive Acid Alkaline Concentration Sensor

    Digital Inductive Acid Alkaline Concentration Sensor

    ★ Model: DDG-GYW

    ★ Measure range:  HNO3: 0~25.00%;

    H2SO4: 0~25.00%  92%~100%

    HCL: 0~20.00%  25~40.00)%;

    NaOH: 0~15.00%  20~40.00)%; 

    ★ Protocol: 4-20mA or RS485 signal output

    ★ Power Supply: DC12V-24V

    ★ Features: Strong anti-interference, High accuracy

    ★ Application: Chemical, Waste water, River water, Power plant

  • Online Inductive Acid Alkaline Concentration Sensor

    Online Inductive Acid Alkaline Concentration Sensor

    ★ Model: DDG-GY

    ★ Measure range:  

    HNO3: 0~25.00%; H2SO4: 0~25.00% 

    HCL: 0~20.00% ; NaOH: 0~15.00% ; 

    ★ Protocol: 4-20mA or RS485 signal output

    ★ Power Supply: DC12V-24V

    ★ Features: Strong anti-interference, High accuracy

    ★ Application: Chemical, Waste water, River water, Power plant

  • Online Color Meter

    Online Color Meter

    ★ Model No: SD-500p

    ★ Protocol: Modbus RTU RS485 

    ★ Power Supply:  AC 100~230V or DC24V

    ★ Features: Data logger with 8G storage, Wide range 0~500.0PCU

    ★ Application: Drinking water, surface water, industry water treatment, wastewater 

  • IoT Digital pH Sensor

    IoT Digital pH Sensor

    ★ Model No: BH-485-PH

    ★ Protocol:  Modbus RTU RS485

    ★ Power Supply: DC12V-24V

    ★ Features: Rapid response, strong anti-interference ability

    ★ Application: Waste water, river water, swimming pool

  • IoT Digital Modbus RS485 pH Sensor

    IoT Digital Modbus RS485 pH Sensor

    ★ Model No: BH-485-PH8012

    ★ Protocol:  Modbus RTU RS485

    ★ Power Supply: DC12V-24V

    ★ Features: Rapid response, strong anti-interference ability

    ★ Application: Waste water, river water, swimming pool

  • IoT Digital Inductive Conductivity/TDS/Salinity Sensor

    IoT Digital Inductive Conductivity/TDS/Salinity Sensor

    ★ Measure range: 0-2000ms/cm

    ★ Protocol: 4-20mA or RS485 signal output

    ★ Power Supply: DC12V-24V

    ★ Features: Strong anti-interference, High accuracy

    ★ Application: Chemical, Waste water, River water, Power plant

     

123456 Next > >> Page 1 / 9