PH&ORP

  • New Industrial PH&ORP Meter

    New Industrial PH&ORP Meter

    Model No: PHG-2081Pro

    ★ Protocol: Modbus RTU RS485 or 4-20mA 

    ★ Measure Parameters: pH,ORP, Temperature

    ★ Application: power plant, fermentation, tap water, industrial water

    ★ Features: IP65 protection grade, 90-260VAC wide power supply

  • New Online PH&ORP Meter

    New Online PH&ORP Meter

    Model No: PHG-2091Pro

    ★ Protocol: Modbus RTU RS485 or 4-20mA 

    ★ Measure Parameters: pH,ORP, Temperature

    ★ Application: domestic water, RO plant, drinking water

    ★ Features: IP65 protection grade, 90-260VAC wide power supply

  • IoT Digital pH Sensor

    IoT Digital pH Sensor

    ★ Model No: BH-485-PH

    ★ Protocol:  Modbus RTU RS485

    ★ Power Supply: DC12V-24V

    ★ Features: Rapid response, strong anti-interference ability

    ★ Application: Waste water, river water, swimming pool

  • IoT Digital ORP Sensor

    IoT Digital ORP Sensor

    ★ Model No: BH-485-ORP

    ★ Protocol:  Modbus RTU RS485

    ★ Power Supply: DC12V-24V

    ★ Features: Rapid response, strong anti-interference ability

    ★ Application: Waste water, river water, swimming pool

  • Laboratory pH Sensor

    Laboratory pH Sensor

    E-301 pH sensor In PH measurement, the used electrode is also known as the primary battery. The primary battery is a system, whose role is to transfer chemical energy into electrical energy. The voltage of the battery is called the electromotive force (EMF). This electromotive force (EMF) is composed of two half-batteries. One half-battery is called the measuring electrode, and its potential is related to the specific ion activity; the other half-battery is the reference battery, often called the reference electrode, which is generally interlinked with the measurement solution, and connected to the measuring instrument.

  • PH5806-S8 High-temperature PH Sensor

    PH5806-S8 High-temperature PH Sensor

    It adopts heat-resisting gel dielectric and solid dielectric double liquid junction structure; in the circumstances when the electrode is not connected to the back pressure, the withstand pressure is 0.4MPa. It can be directly used for l30℃ sterilization.

  • PH5806-K8S High-temperature PH Sensor

    PH5806-K8S High-temperature PH Sensor

    There is no need for additional dielectric and there is a little amount of maintenance.

    It adopts K8S and PGl3.5 thread socket, which can be replaced by any overseas electrode.

  • PH5806 High Temperature PH Sensor

    PH5806 High Temperature PH Sensor

    For the electrode length, there are 120, 150, 210, 260 and 320 mm available; according to different needs, they are optional.

  • PH5803-K8S Industrial ORP Sensor

    PH5803-K8S Industrial ORP Sensor

    It adopts heat-resisting gel dielectric and solid dielectric double liquid junction structure; in the circumstances when the electrode is not connected to the back pressure, the withstand pressure is 0~6Bar. It can be directly used for l30℃ sterilization.

  • PH8083A&AH Industrial ORP Sensor

    PH8083A&AH Industrial ORP Sensor

    It adopts gel or solid electrolyte, resisting pressure and helping reduce resistance; low resistance sensitive membrane.

  • PH8022 Industrial Pure Water PH Sensor

    PH8022 Industrial Pure Water PH Sensor

    The diffusion potential is very stable; large-area diaphragm surrounds the glass diaphragm bubbles, so that the distance from the reference diaphragm to the glass diaphragm is near and constant; the ions diffused from diaphragm and the glass electrode quickly form a complete measurement circuit to respond quickly, so that the diffusion potential is not easy to be affected by the outside flow rate and is thus very stable!

  • PH8012 Industrial Waste Water PH Sensor

    PH8012 Industrial Waste Water PH Sensor

    In PH measurement, the used electrode is also known as the primary battery. The primary battery is a system, whose role is to transfer chemical energy into electrical energy. 

12 Next > >> Page 1 / 2