PH&ORP
-
New Industrial PH&ORP Meter
★ Model No: PHG-2081Pro
★ Protocol: Modbus RTU RS485 or 4-20mA
★ Measure Parameters: pH,ORP, Temperature
★ Application: power plant, fermentation, tap water, industrial water
★ Features: IP65 protection grade, 90-260VAC wide power supply
-
New Online PH&ORP Meter
★ Model No: PHG-2091Pro
★ Protocol: Modbus RTU RS485 or 4-20mA
★ Measure Parameters: pH,ORP, Temperature
★ Application: domestic water, RO plant, drinking water
★ Features: IP65 protection grade, 90-260VAC wide power supply
-
IoT Digital pH Sensor
★ Model No: BH-485-PH
★ Protocol: Modbus RTU RS485
★ Power Supply: DC12V-24V
★ Features: Rapid response, strong anti-interference ability
★ Application: Waste water, river water, swimming pool
-
IoT Digital ORP Sensor
★ Model No: BH-485-ORP
★ Protocol: Modbus RTU RS485
★ Power Supply: DC12V-24V
★ Features: Rapid response, strong anti-interference ability
★ Application: Waste water, river water, swimming pool
-
Laboratory pH Sensor
E-301 pH sensor In PH measurement, the used electrode is also known as the primary battery. The primary battery is a system, whose role is to transfer chemical energy into electrical energy. The voltage of the battery is called the electromotive force (EMF). This electromotive force (EMF) is composed of two half-batteries. One half-battery is called the measuring electrode, and its potential is related to the specific ion activity; the other half-battery is the reference battery, often called the reference electrode, which is generally interlinked with the measurement solution, and connected to the measuring instrument.
-
PH5806-S8 High-temperature PH Sensor
It adopts heat-resisting gel dielectric and solid dielectric double liquid junction structure; in the circumstances when the electrode is not connected to the back pressure, the withstand pressure is 0.4MPa. It can be directly used for l30℃ sterilization.
-
PH5806-K8S High-temperature PH Sensor
There is no need for additional dielectric and there is a little amount of maintenance.
It adopts K8S and PGl3.5 thread socket, which can be replaced by any overseas electrode.
-
PH5806 High Temperature PH Sensor
For the electrode length, there are 120, 150, 210, 260 and 320 mm available; according to different needs, they are optional.
-
PH5803-K8S Industrial ORP Sensor
It adopts heat-resisting gel dielectric and solid dielectric double liquid junction structure; in the circumstances when the electrode is not connected to the back pressure, the withstand pressure is 0~6Bar. It can be directly used for l30℃ sterilization.
-
PH8083A&AH Industrial ORP Sensor
It adopts gel or solid electrolyte, resisting pressure and helping reduce resistance; low resistance sensitive membrane.
-
PH8022 Industrial Pure Water PH Sensor
The diffusion potential is very stable; large-area diaphragm surrounds the glass diaphragm bubbles, so that the distance from the reference diaphragm to the glass diaphragm is near and constant; the ions diffused from diaphragm and the glass electrode quickly form a complete measurement circuit to respond quickly, so that the diffusion potential is not easy to be affected by the outside flow rate and is thus very stable!
-
PH8012 Industrial Waste Water PH Sensor
In PH measurement, the used electrode is also known as the primary battery. The primary battery is a system, whose role is to transfer chemical energy into electrical energy.