China Wholesale Dissolved Oxygen Meter Price Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU Detail:
|
DOG-208F Dissolved Oxygen Electrode applicable for Polarography Principle |
| With platinum (Pt) as cathode and Ag / AgCl as anode |
| The electrolyte is 0.1 M potassium chloride (KCI). |
| The silicone rubber permeable membrane imported from U.S. serves as the permeable |
| membrane. |
| It has silicone rubber and steel gauze. |
| It is featured by collision resistance, corrosion resistance, high.temperature resistance, shape |
| retention and other performances |
| Measuring range: 0-100ug/L 0-20mg/L |
| Electrode material: 316L stainless steel |
| Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
| Sensor life: >3 years |
| Cable length: 5m (double shielded) |
| Detection lower Limit: 0.1ug/L(ppb)(20℃) |
| Measurement upper limit: 20mg/l(ppm) |
| Response time: ≤3min(90%, 20℃) |
| Polarization time: >8h |
| Minimum flow rate: 5cm/s; 515 L/h |
| Drift: <3%/month |
| Measurement error: <±1 ppb |
| Air current: 50-80nA Note: Maximum current 20-25 uA |
| Polarization voltage: 0.7V |
| Zero Oxygen: <5ppb(60min) |
| Calibration intervals: >60 days |
| Measured water temperature:0~60℃ |
| Measuring range: 0-100ug/L 0-20mg/L |
| Electrode material: 316L stainless steel |
| Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
| Sensor life: >3 years |
| Cable length: 5m (double shielded) |
| Detection lower Limit: 0.1ug/L(ppb)(20℃) |
| Measurement upper limit: 20mg/l(ppm) |
| Response time: ≤3min(90%, 20℃) |
| Polarization time: >8h |
| Minimum flow rate: 5cm/s; 515 L/h |
| Drift: <3%/month |
| Measurement error: <±1 ppb |
| Air current: 50-80nA Note: Maximum current 20-25 uA |
| Polarization voltage: 0.7V |
| Zero Oxygen: <5ppb(60min) |
| Calibration intervals: >60 days |
| Measured water temperature:0~60℃ |
Applied to thermal power plants, power plant desalted water,.
boiler feed water etc places of trace oxygen content.
Product detail pictures:
Related Product Guide:
We are also focusing on enhancing the things administration and QC program in order that we could keep fantastic advantage within the fiercely-competitive enterprise for China Wholesale Dissolved Oxygen Meter Price Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU , The product will supply to all over the world, such as: Slovak Republic, Moldova, Vancouver, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information if you have any questions. We are glad to work for every client.