Wholesale China dissolved oxygen probe Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU Detail:
|
DOG-208F Dissolved Oxygen Electrode applicable for Polarography Principle |
| With platinum (Pt) as cathode and Ag / AgCl as anode |
| The electrolyte is 0.1 M potassium chloride (KCI). |
| The silicone rubber permeable membrane imported from U.S. serves as the permeable |
| membrane. |
| It has silicone rubber and steel gauze. |
| It is featured by collision resistance, corrosion resistance, high.temperature resistance, shape |
| retention and other performances |
| Measuring range: 0-100ug/L 0-20mg/L |
| Electrode material: 316L stainless steel |
| Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
| Sensor life: >3 years |
| Cable length: 5m (double shielded) |
| Detection lower Limit: 0.1ug/L(ppb)(20℃) |
| Measurement upper limit: 20mg/l(ppm) |
| Response time: ≤3min(90%, 20℃) |
| Polarization time: >8h |
| Minimum flow rate: 5cm/s; 515 L/h |
| Drift: <3%/month |
| Measurement error: <±1 ppb |
| Air current: 50-80nA Note: Maximum current 20-25 uA |
| Polarization voltage: 0.7V |
| Zero Oxygen: <5ppb(60min) |
| Calibration intervals: >60 days |
| Measured water temperature:0~60℃ |
| Measuring range: 0-100ug/L 0-20mg/L |
| Electrode material: 316L stainless steel |
| Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
| Sensor life: >3 years |
| Cable length: 5m (double shielded) |
| Detection lower Limit: 0.1ug/L(ppb)(20℃) |
| Measurement upper limit: 20mg/l(ppm) |
| Response time: ≤3min(90%, 20℃) |
| Polarization time: >8h |
| Minimum flow rate: 5cm/s; 515 L/h |
| Drift: <3%/month |
| Measurement error: <±1 ppb |
| Air current: 50-80nA Note: Maximum current 20-25 uA |
| Polarization voltage: 0.7V |
| Zero Oxygen: <5ppb(60min) |
| Calibration intervals: >60 days |
| Measured water temperature:0~60℃ |
Applied to thermal power plants, power plant desalted water,.
boiler feed water etc places of trace oxygen content.
Product detail pictures:
Related Product Guide:
Our target is always to satisfy our customers by offering golden support, superior value and high quality for Wholesale China dissolved oxygen probe Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU , The product will supply to all over the world, such as: Brazil, Berlin, Denver, Our company always provides good quality and reasonable price for our customers. In our efforts, we already have many shops in Guangzhou and our products have won praise from customers worldwide. Our mission has always been simple: To delight our customers with best quality hair products and deliver on time. Welcome new and old customers to contact us for the future long term business relationships.