Historical Products
-
Industrial PH/ORP Analyzer
★ Model No: pHG-2091
★ Protocol: Modbus RTU RS485 or 4-20mA
★ Power Supply: AC220V ±22V
★Measure Parameters: pH,ORP, Temperature
★ Features: IP65 protection grade
★ Application: domestic water, RO plant, drinking water
-
Industrial Dissolved Oxygen Meter
★ Model No: DOG-2092
★ Protocol: Modbus RTU RS485 or 4-20mA
★ Power Supply: AC220V ±22V
★Measure Parameters: DO, Temperature
★ Features: IP65 protection grade
★ Application: domestic water, RO plant, drinking water -
Industrial PH/ORP Analyzer
★ Model No: ORP-2096
★ Protocol: Modbus RTU RS485 or 4-20mA
★ Power Supply: AC220V ±22V
★Measure Parameters: pH,ORP, Temperature
★ Features: IP65 protection grade
★ Application: domestic water, RO plant, drinking water
-
Industrial Online Conductivity Meter
★ Model No: DDG-2090
★ Protocol: Modbus RTU RS485 or 4-20mA
★ Power Supply: AC220V ±22V
★Measure Parameters: Conductivity, Temperature
★ Features: IP65 protection grade
★ Application: domestic water, RO plant, drinking water -
Integrated Low Range Turbidity Sensor With Display
★ Model No: BH-485-TU
★ A continuous reading turbidity meter designed for low range turbidity monitoring
★ EPA principle 90-degree scattering method, specially used for low-range turbidity monitoring;
★ The data is stable and reproducible
★ Simple cleaning and maintenance;
★ Protocol: Modbus RTU RS485
★ Power Supply: DC24V(19-36V)
★ Application: surface water, tap water factory water, secondary water supply etc
-
Digital Inductive Acid Alkaline Concentration Sensor
★ Model: DDG-GYW
★ Measure range: HNO3: 0~25.00%;
H2SO4: 0~25.00% 92%~100%
HCL: 0~20.00% 25~40.00)%;
NaOH: 0~15.00% 20~40.00)%;
★ Protocol: 4-20mA or RS485 signal output
★ Power Supply: DC12V-24V
★ Features: Strong anti-interference, High accuracy
★ Application: Chemical, Waste water, River water, Power plant
-
Online Inductive Digital Acid Alkaline Concentration Sensor
★ Model: DDG-GYG
★ Measure range: HNO3: 0~25.00%; H2SO4: 0~25.00%;
HCL: 0~20.00%; NaOH: 0~15.00% ;
★ Protocol: 4-20mA or RS485 signal output
★ Power Supply: DC12V-24V
★ Features: Strong anti-interference, High accuracy
★ Application: Chemical, Waste water, River water, Power plant
-
Online Inductive Acid Alkaline Concentration Sensor
★ Model: DDG-GY
★ Measure range:
HNO3: 0~25.00%; H2SO4: 0~25.00%
HCL: 0~20.00% ; NaOH: 0~15.00% ;
★ Protocol: 4-20mA or RS485 signal output
★ Power Supply: DC12V-24V
★ Features: Strong anti-interference, High accuracy
★ Application: Chemical, Waste water, River water, Power plant


