Wholesale China Residual Chlorine Electrode Factory Suppliers - CL-2059A Online Residual Chlorine Analyzer – BOQU

Short Description:


  • facebook
  • sns02
  • sns04

Product Detail

Related Video

Feedback (2)

owing to fantastic assistance, a variety of high quality goods, aggressive rates and efficient delivery, we love a very good popularity among our customers. We are an energetic firm with wide market for Chemical Oxygen Demand Meter , Portable Ph Conductivity Tds Meter , Online Ph Sensor , Our professional technical team will be wholeheartedly at your service. We sincerely welcome you to visit our website and company and send us your inquiry.
Wholesale China Residual Chlorine Electrode Factory Suppliers - CL-2059A Online Residual Chlorine Analyzer – BOQU Detail:

Highly intelligent: CL-2059A Industrial online residual chlorine analyzer adopts industry leading overall design
concept of the core components to ensure high-quality, import instruments.
High and low alarm: hardware isolation, each channel can be arbitrarily chosen measurement parameters, can be
hysteresis.
Temperature compensation: 0 ~ 50 ℃ automatic temperature compensation
Waterproof and dustproof: good sealing instrument.
Menu: Easy operation menu
Multi-screen display: There are three kinds of instrument display, user-friendly display for the different
requirements.
Chlorine calibration: provide chlorine zero and slope calibration, clear menu design.
1. Measuring range     
Residual chlorine: 0-20.00mg/L,      Resolution: 0.01mg/L;
Temperature: 0- 99.9 ℃         Resolution: 0.1 ℃
2.Accuracy: Chlorine: better than ± 1% or ± 0.01mg /L.
3.Temperature: better than ± 0.5 ℃ (0 ~ 50.0 ℃)
4.Minmum detection: 0.01mg /L
5.Repeatability Chlorine: ± 0.01mg / L
6.Stability Chlorine: ± 0.01 (mg / L) / 24h
7.Current isolated output: 4 ~ 20 mA(load <750 Ω) current output, measurement parameters can be selected 
independently (FAC, T)
8.Output current error: ≤ ± 1% FS
9. High and low alarm: AC220V, 5A, each channel can be selected independently measured parameters  
corresponding (FAC, T)
10.Alarm hysteresis: can be set according to the selected parameters
11.Communication: RS485 (optional)
12.Working environment: Temperature 0 ~ 60 ℃, Relative humidity <85%
It can be convenient to computer monitoring and communication
13.Installation type: Opening type, panel mounted.
14.Dimensions: 96 (L) × 96 (W) × 118 (D) mm; Hole Size: 92x92mm
15.Weight: 0.5kg 

chlorine analyzer, constant-current chlorine electrode, constant-current groove (3-hole), electrode cable (5m)


Product detail pictures:

Wholesale China Residual Chlorine Electrode Factory Suppliers - CL-2059A Online Residual Chlorine Analyzer  – BOQU detail pictures

Wholesale China Residual Chlorine Electrode Factory Suppliers - CL-2059A Online Residual Chlorine Analyzer  – BOQU detail pictures


Related Product Guide:

We love an incredibly fantastic standing amid our consumers for our superb item high quality, aggressive rate and also the finest assistance for Wholesale China Residual Chlorine Electrode Factory Suppliers - CL-2059A Online Residual Chlorine Analyzer – BOQU , The product will supply to all over the world, such as: Surabaya, Swiss, Slovenia, For anyone who is keen on any of our goods right after you view our product list, please really feel absolutely free to get in touch with us for inquiries. You are able to send us emails and contact us for consultation and we shall respond to you as soon as we can. If it's easy, you may locate out our address in our web-site and come to our business for far more information of our products by your self. We are always ready to construct extended and steady co-operation relations with any possible customers in the related fields.
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Ruth from Serbia - 2018.09.21 11:01
    We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Heloise from Cambodia - 2018.07.26 16:51
    Write your message here and send it to us