Wholesale China Residual Chlorine Analyzer&Sensor Manufacturers Pricelist - YLG-2058-01 Industrial Residual Chlorine Sensor – BOQU Detail:
Working principle
Electrolyte and osmotic membrane separates the electrolytic cell and water samples, permeable membranes can selectively to ClO- penetration; between the two electrode has a fixed potential difference, current intensity generated can be converted into residual chlorine concentration.
At the cathode: ClO- + 2H+ + 2e- → Cl-+ H2O
At the anode: Cl- + Ag → AgCl + e-
Because in a certain temperature and pH conditions, HOCl, ClO- and residual chlorine between fixed conversion relationship, in this way can measure the residual chlorine.
Product detail pictures:
Related Product Guide:
Our concentrate on is always to consolidate and enhance the excellent and service of present solutions, in the meantime regularly develop new products to meet distinctive customers' demands for Wholesale China Residual Chlorine Analyzer&Sensor Manufacturers Pricelist - YLG-2058-01 Industrial Residual Chlorine Sensor – BOQU , The product will supply to all over the world, such as: Macedonia, Qatar, New Orleans, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.