Wholesale China Residual Chlorine Analyzer&Sensor Manufacturers Pricelist - YLG-2058-01 Industrial Residual Chlorine Sensor – BOQU Detail:
Working principle
Electrolyte and osmotic membrane separates the electrolytic cell and water samples, permeable membranes can selectively to ClO- penetration; between the two electrode has a fixed potential difference, current intensity generated can be converted into residual chlorine concentration.
At the cathode: ClO- + 2H+ + 2e- → Cl-+ H2O
At the anode: Cl- + Ag → AgCl + e-
Because in a certain temperature and pH conditions, HOCl, ClO- and residual chlorine between fixed conversion relationship, in this way can measure the residual chlorine.
Product detail pictures:
Related Product Guide:
We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for Wholesale China Residual Chlorine Analyzer&Sensor Manufacturers Pricelist - YLG-2058-01 Industrial Residual Chlorine Sensor – BOQU , The product will supply to all over the world, such as: Nairobi, Canada, Turin, With the spirit of "credit first, development through innovation, sincere cooperation and joint growth", our company is striving to create a brilliant future with you, so as to become a most valuable platform for exporting our products in China!