Wholesale China Optical Dissolved Oxygen Probe Factory Suppliers - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU Detail:
|
DOG-208F Dissolved Oxygen Electrode applicable for Polarography Principle |
| With platinum (Pt) as cathode and Ag / AgCl as anode |
| The electrolyte is 0.1 M potassium chloride (KCI). |
| The silicone rubber permeable membrane imported from U.S. serves as the permeable |
| membrane. |
| It has silicone rubber and steel gauze. |
| It is featured by collision resistance, corrosion resistance, high.temperature resistance, shape |
| retention and other performances |
| Measuring range: 0-100ug/L 0-20mg/L |
| Electrode material: 316L stainless steel |
| Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
| Sensor life: >3 years |
| Cable length: 5m (double shielded) |
| Detection lower Limit: 0.1ug/L(ppb)(20℃) |
| Measurement upper limit: 20mg/l(ppm) |
| Response time: ≤3min(90%, 20℃) |
| Polarization time: >8h |
| Minimum flow rate: 5cm/s; 515 L/h |
| Drift: <3%/month |
| Measurement error: <±1 ppb |
| Air current: 50-80nA Note: Maximum current 20-25 uA |
| Polarization voltage: 0.7V |
| Zero Oxygen: <5ppb(60min) |
| Calibration intervals: >60 days |
| Measured water temperature:0~60℃ |
| Measuring range: 0-100ug/L 0-20mg/L |
| Electrode material: 316L stainless steel |
| Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
| Sensor life: >3 years |
| Cable length: 5m (double shielded) |
| Detection lower Limit: 0.1ug/L(ppb)(20℃) |
| Measurement upper limit: 20mg/l(ppm) |
| Response time: ≤3min(90%, 20℃) |
| Polarization time: >8h |
| Minimum flow rate: 5cm/s; 515 L/h |
| Drift: <3%/month |
| Measurement error: <±1 ppb |
| Air current: 50-80nA Note: Maximum current 20-25 uA |
| Polarization voltage: 0.7V |
| Zero Oxygen: <5ppb(60min) |
| Calibration intervals: >60 days |
| Measured water temperature:0~60℃ |
Applied to thermal power plants, power plant desalted water,.
boiler feed water etc places of trace oxygen content.
Product detail pictures:
Related Product Guide:
We've got a highly efficient group to deal with inquiries from shoppers. Our purpose is "100% client fulfillment by our product high-quality, price tag & our staff service" and enjoy a superb reputation amongst clientele. With quite a few factories, we will provide a wide variety of Wholesale China Optical Dissolved Oxygen Probe Factory Suppliers - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU , The product will supply to all over the world, such as: Sudan, Cancun, Bulgaria, Regarding quality as survival, prestige as guarantee, innovation as motive force, development along with advanced technology, our group hopes to make progress together with you and make untiring efforts for the bright future of this industry.