Wholesale China Dissolved Oxygen Meter For Water Quotes Manufacturer - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU Detail:
DOG-208F Dissolved Oxygen Electrode applicable for Polarography Principle |
With platinum (Pt) as cathode and Ag / AgCl as anode |
The electrolyte is 0.1 M potassium chloride (KCI). |
The silicone rubber permeable membrane imported from U.S. serves as the permeable |
membrane. |
It has silicone rubber and steel gauze. |
It is featured by collision resistance, corrosion resistance, high.temperature resistance, shape |
retention and other performances |
Measuring range: 0-100ug/L 0-20mg/L |
Electrode material: 316L stainless steel |
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
Sensor life: >3 years |
Cable length: 5m (double shielded) |
Detection lower Limit: 0.1ug/L(ppb)(20℃) |
Measurement upper limit: 20mg/l(ppm) |
Response time: ≤3min(90%, 20℃) |
Polarization time: >8h |
Minimum flow rate: 5cm/s; 515 L/h |
Drift: <3%/month |
Measurement error: <±1 ppb |
Air current: 50-80nA Note: Maximum current 20-25 uA |
Polarization voltage: 0.7V |
Zero Oxygen: <5ppb(60min) |
Calibration intervals: >60 days |
Measured water temperature:0~60℃ |
Measuring range: 0-100ug/L 0-20mg/L |
Electrode material: 316L stainless steel |
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc |
Sensor life: >3 years |
Cable length: 5m (double shielded) |
Detection lower Limit: 0.1ug/L(ppb)(20℃) |
Measurement upper limit: 20mg/l(ppm) |
Response time: ≤3min(90%, 20℃) |
Polarization time: >8h |
Minimum flow rate: 5cm/s; 515 L/h |
Drift: <3%/month |
Measurement error: <±1 ppb |
Air current: 50-80nA Note: Maximum current 20-25 uA |
Polarization voltage: 0.7V |
Zero Oxygen: <5ppb(60min) |
Calibration intervals: >60 days |
Measured water temperature:0~60℃ |
Applied to thermal power plants, power plant desalted water,.
boiler feed water etc places of trace oxygen content.
Product detail pictures:

Related Product Guide:
The corporation keeps to the operation concept "scientific management, superior quality and performance primacy, consumer supreme for Wholesale China Dissolved Oxygen Meter For Water Quotes Manufacturer - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU , The product will supply to all over the world, such as: Philippines, Hungary, Hongkong, Our company sticks to the principle of "high quality, reasonable price and timely delivery". We sincerely hope to establish good cooperative relationships with our new and old business partners from all parts of the world. We hope to work with you and serve you with our excellent goods and services. Welcome to join us!

A good manufacturers, we have cooperated twice, good quality and good service attitude.

Write your message here and send it to us