We have released three self-developed water quality analysis instruments. These three instruments were developed by our R&D department based on customer feedback to meet more detailed market demands. Each one has undergone functional upgrades in the corresponding working conditions, making water quality monitoring more accurate, intelligent and simple. Here is a brief introduction to the three instruments:
The newly released portable fluorescence dissolved oxygen meter: It adopts the optical measurement principle of fluorescence quenching effect, and calculates the dissolved oxygen concentration by exciting the fluorescent dye with a blue LED and detecting the quenching time of the red fluorescence. It has the advantages of high measurement accuracy, strong anti-interference ability, and easy maintenance.
Model |
DOS-1808 |
Measurement principle |
Fluorescence principle |
Measuring range |
DO:0-20mg/L(0-20ppm);0-200%,Temp:0-50℃ |
Accuracy |
±2~3% |
Pressure range |
≤0.3Mpa |
Class of protection |
IP68/NEMA6P |
Main materials |
ABS, O-ring: fluororubber, cable: PUR |
Cable |
5m |
Sensor weight |
0.4KG |
Sensor size |
32mm*170mm |
Calibration |
Calibration of saturated water |
Storage temperature |
-15 to 65℃ |
The newly released ppb-level dissolved oxygen meter DOG-2082Pro-L: It can detect extremely low concentrations of dissolved oxygen (ppb level, i.e., micrograms per liter), and is suitable for strict environmental monitoring (such as power plants, semiconductor industries, etc.).
Model | DOS-2082Pro-L |
Measuring range | 0-20mg/L、0-100ug/L;Temp:0-50℃ |
Power supply | 100V-240V AC 50/60Hz (alternative:24V DC) |
Accuracy | <±1.5%FS or 1µg/L(Take the larger value) |
Response time | 90% of the change is achieved within 60 seconds at 25℃ |
Repeatability | ±0.5%FS |
Stability | ±1.0%FS |
Output | Two ways 4-20 mA |
Communication | RS485 |
Water sample temperature | 0-50℃ |
water discharge | 5-15L/h |
Temperature compensation | 30K |
Calibration | Saturated oxygen calibration, zero point calibration, and known concentration calibration |
The newly released multi-parameter water quality analyzer MPG-6099DPD: It can simultaneously monitor residual chlorine, turbidity, pH, ORP, conductivity, and temperature. Its most prominent feature is the use of colorimetric method to measure residual chlorine, which offers higher measurement accuracy. Secondly, the independent yet integrated design of each unit is also a major selling point, allowing each module to be maintained separately without the need for overall disassembly, thus reducing maintenance costs.
Model |
MPG-6099DPD |
Measuring Principle |
Residual chlorine:DPD |
Turbidity: Infrared light scattering absorption method |
|
Residual chlorine |
|
Measuring range |
Residual chlorine:0-10mg/L;; |
Turbidity:0-2NTU |
|
pH:0-14pH |
|
ORP:-2000mV~+2000 mV;(alternative) |
|
Conductivity:0-2000uS/cm; |
|
Temperature:0-60℃ |
|
Accuracy |
Residual chlorine:0-5mg/L:±5% or ±0.03mg/L;6~10mg/L:±10% |
Turbidity: ±2% or ±0.015NTU(Take the larger value) |
|
pH:±0. 1pH; |
|
ORP:±20mV |
|
Conductivity:±1%FS |
|
Temperature: ±0.5℃ |
|
Display Screen |
10-inch color LCD touch screen display |
Dimension |
500mm×716mm×250mm |
Data Storage |
The data can be stored for 3 years and supports export via USB flash drive |
Communication Protocol |
RS485 Modbus RTU |
Interval of Measurement |
Residual chlorine:The measurement interval can be set |
pH/ORP/ conductivity/temperature/turbidity:Continuous measurement |
|
Dosage of Reagent |
Residual chlorine: 5000 sets of data |
Operating Conditions |
Sample flow rate: 250-1200mL/min, inlet pressure: 1bar (≤1.2bar), sample temperature: 5℃ - 40℃ |
Protection level/material |
IP55,ABS |
Inlet and outlet pipes |
nlet pipe Φ6, outlet pipe Φ10;Overflow pipe Φ10 |
Post time: Jun-20-2025