Always customer-oriented, and it's our ultimate target to be not only the most reliable, trustable and honest supplier, but also the partner for our customers for Acid Alkaline Concentration、Acid Alkaline Concentration Meter , Ph Digital Sensor , Online Silicate Meter , We welcome shoppers, business enterprise associations and close friends from all sections with the globe to contact us and seek cooperation for mutual added benefits.
China Wholesale Online Dissolved Oxygen Analyzer Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU Detail:

DOG-208F Dissolved Oxygen Electrode applicable for Polarography Principle

With platinum (Pt) as cathode and Ag / AgCl as anode
The electrolyte is 0.1 M potassium chloride (KCI).
The silicone rubber permeable membrane imported from U.S. serves as the permeable
membrane.
It has silicone rubber and steel gauze.
It is featured by collision resistance, corrosion resistance, high.temperature resistance, shape
retention and other performances
Measuring range: 0-100ug/L 0-20mg/L
Electrode material: 316L stainless steel
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc
Sensor life: >3 years
Cable length: 5m (double shielded)
Detection lower Limit: 0.1ug/L(ppb)(20℃)
Measurement upper limit: 20mg/l(ppm)
Response time: ≤3min(90%, 20℃)
Polarization time: >8h
Minimum flow rate: 5cm/s; 515 L/h
Drift: <3%/month
Measurement error: <±1 ppb
Air current: 50-80nA   Note: Maximum current 20-25 uA
Polarization voltage: 0.7V
Zero Oxygen: <5ppb(60min)
Calibration intervals: >60 days
Measured water temperature:0~60℃
Measuring range: 0-100ug/L 0-20mg/L
Electrode material: 316L stainless steel
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc
Sensor life: >3 years
Cable length: 5m (double shielded)
Detection lower Limit: 0.1ug/L(ppb)(20℃)
Measurement upper limit: 20mg/l(ppm)
Response time: ≤3min(90%, 20℃)
Polarization time: >8h
Minimum flow rate: 5cm/s; 515 L/h
Drift: <3%/month
Measurement error: <±1 ppb
Air current: 50-80nA   Note: Maximum current 20-25 uA
Polarization voltage: 0.7V
Zero Oxygen: <5ppb(60min)
Calibration intervals: >60 days
Measured water temperature:0~60℃

 

Applied to thermal power plants, power plant desalted water,.

boiler feed water etc places of trace oxygen content.


Product detail pictures:

China Wholesale Online Dissolved Oxygen Analyzer Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor  – BOQU detail pictures


Related Product Guide:

We believe in: Innovation is our soul and spirit. Quality is our life. Customer need is our God for China Wholesale Online Dissolved Oxygen Analyzer Manufacturers Pricelist - DOG-208F Industrial Dissolved Oxygen Sensor – BOQU , The product will supply to all over the world, such as: Venezuela, Mecca, Vietnam, Regarding quality as survival, prestige as guarantee, innovation as motive force, development along with advanced technology, our group hopes to make progress together with you and make untiring efforts for the bright future of this industry.
  • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By ron gravatt from Lebanon - 2018.06.18 19:26
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Antonia from Paraguay - 2017.10.27 12:12
    Write your message here and send it to us