Steam Water Analysis System(SWAS)

A Steam Water Analysis System (SWAS) is an integrated online monitoring system designed to continuously analyze the quality of steam, boiler water, feedwater, condensate, and other water-steam cycle streams in industrial steam and power-generation systems. By continuously monitoring key water quality parameters such as pH, conductivity, dissolved oxygen, silica, sodium, phosphate, and chloride, a SWAS helps operators detect contamination, corrosion, scaling, and other potential problems at an early stage.
In a typical SWAS, water or steam samples are extracted from different points in the process and then conditioned through cooling, pressure reduction, filtration, and flow control before entering online analyzers. The measurement data can be transmitted to a DCS, PLC, SCADA, or plant control system, enabling real-time monitoring, alarm management, and process optimization.
Maintaining proper water and steam chemistry is critical because impurities in the water-steam cycle can cause boiler scaling, corrosion, turbine deposits, reduced heat-transfer efficiency, and equipment damage. A well-designed SWAS therefore plays an important role in improving equipment reliability, reducing maintenance costs, increasing energy efficiency, and extending the service life of critical equipment.

In a thermal power plant, water goes through a continuous cycle:
Raw Water → Water Treatment → Demineralized Water → Boiler Feedwater → Boiler → Steam → Turbine → Condenser → Condensate → Feedwater
During this process, even a small amount of contamination or a change in water chemistry can create serious problems.
For example, excessive conductivity may indicate contamination. Low pH can accelerate corrosion, while excessive dissolved oxygen can promote oxygen corrosion. Silica can be carried into steam and deposited on turbine blades, reducing turbine efficiency.
Therefore, the purpose of SWAS is not simply to "measure water quality." It is to provide continuous monitoring of critical chemical parameters throughout the water-steam cycle, allowing operators to identify abnormal conditions at an early stage.
The selection of water quality analyzers is one of the most important steps when designing a SWAS.
It is not enough to simply choose an analyzer according to the parameter that needs to be measured.
The sampling conditions and process requirements must also be considered.This means the analyzer configuration should be customized according to the monitoring objective rather than using the same analyzer combination at every sampling point.
As an experienced manufacturer of water quality monitoring equipment, Shanghai Boqu Instrument Co., Ltd. develops and supplies a range of water quality analyzers and water quality sensors that can be applied to industrial water monitoring and SWAS-related applications.
Its product portfolio covers multiple analytical parameters, including pH, conductivity, dissolved oxygen, turbidity, residual chlorine, and other water quality indicators, providing flexible options for different industrial monitoring requirements.
For SWAS applications, the analyzer and sensor should be selected according to the specific sampling point and process conditions. For example, a power plant may require different measurement configurations for feedwater, condensate, boiler water, demineralized water, and cooling water.
The use of suitable online analyzers and sensors enables continuous measurement and reduces dependence on intermittent laboratory sampling. Combined with an appropriate sampling and conditioning system, these instruments can become an important part of a plant's overall water chemistry monitoring strategy.
For system integrators and power plant operators, this also makes it possible to develop a modular SWAS solution based on the actual process requirements rather than adopting a one-size-fits-all configuration.
Schematic Diagram of Water Quality Monitoring Process in Thermal Power Plants

Recommended Water Analyzer
| Parameters | Model |
| pH | pH2081Pro Online pH Meter |
| Dissolved Oxygen | DOG-2082Pro-L Online Dissolved Oxygen Meter |
| Conductivity | DDG-2080Pro Online Conductivity Meter |
| Silicate | LSGG-5090pro Silicate Analyzer |
| Phosphate | GSGG-5089Pro Phosphate Analyzer |
| Sodium | DWG-5088Pro Sodium Analyzer |
| Hydrazine | LNG-5087pro Hydrazine Analyzer |
| TOC | Total Organic Carbon (TOC) Analyzer |
Measurement Parameter: pH
| Model | PHG-2081Pro | Model | PH-8022 | CPH-800 | ORP-8083A |
| Measuring Range | -2-16pH | Measuring Range | 0-14 pH | ±1900mV | |
| Accuracy | ±0.05 pH | Accuracy | ±0.05pH | ±20mV | |
| Working Temperature | -20-50 ℃ | Applicable Compensation | NTC10K,NTC2.252K,Pt1000 | ||
| Output | One RS485, Two 4-20mA | Applicable Temperature | 0-60 ℃ | ||
| Relay | Two high and low relay /One time relay | Pressure range | Atmospheric Pressure | <0.6 MPa | |
| Power Supply | 90V – 260V AC 50/60Hz (24V alternative) | Connector | Low-noise Cable Goes Out Directly | ||
| Installation Size | 138*138mm | Connection Thread | Upper and Lower 3/4NPT | PG13.5 | PG13.5 |
| Installation | Panel/Wall Installation | Main Material | PC | Glass (Sand Core Penetration) | Glass (Tetrafluoride Permeation) |
| Data Storage | 1000 Groups | Installation | Flow-through/Pipe Installation | Flow-through | Flow-through |
| Waterproof Class | IP65 | Cable Length | 5m (Customizable) | ||
Measurement Parameter: Dissolved Oxygen
| Model | DOG-2082Pro | DOG-2082Pro-L | Model | DOG-208F | DOG-208F-L(Suitable for DOG-2082PRO-L) |
| Range | 0~20mg/L | 0~20mg/L,0-100ug/L | Range | 0-200ug/L | 0-100ug/L |
| Accuracy | ±1%F.S. | <±1.5%F.S. or 1µg/L(Take the larger one) | Accuracy | ±0.1ug/L | <±1.5%F.S or 1µg/L(whichever is greater) |
| Working Temperature | 0~60℃ | 0-50℃ | Temperature Compensation | NTC2.252K, NTC22K, Ptl00, Ptl000 | 30K |
| Output | One-way RS485,two-way 4-20mA | Measure Temperature | 0-50℃ | 0-50℃ | |
| Relay | Two high and low relay /One time relay | Pressure | Atmospheric pressure | <1mpa | |
| Power | 100~240V (24V alternative) | Material | SS316L | POM | |
| Installation Size | 138*138mm | Cable Length | 5m or 10m(Double shielding) | - | |
| Installation Method | Panel/Wall | Installation | Flow-through | Flow-through | |
| Storage | 1000 times | ||||
| Protection Grade | IP65 | ||||
Measurement Parameter: Conductivity/TDS/Salinity/Resistivity
| Model No | DDG-2080Pro | Model No | DDG-0.01 | DDG-0.1 | DDG-1.0 |
| Measure Range | Conductivity: 0-2000000 uS/ cm (0 ~2000 mS/cm); TDS: 0-130000 mg/L(ppm); Salinity: 0-80 g/L(ppt); Resistivity: 0-20 MΩ•cm; Temp: -40-200 ℃. (Measure range depends on related sensor) | Measuring Range | K=0.01 0-20μS/cm | K=0.1 0-200μS/cm | K=1.0 0-2000μS/cm |
| Accuracy | ±2% ;±0.5℃ | Accuracy | ±2% FS | ||
| Working Temerature | 0-60℃ | Temp compensation | Pt1000,NTC10K,NTC2.252K | ||
| Communication | Modbus RTU | Working Temp | 0-60℃ | ||
| Signal Output | One-way RS485,two-way 4-20mA | Electrode Material | Stainless steel, titanium alloy, platinum | ||
| Powwer supply | 90V – 260V AC 50/60Hz (24V alternative) | Pressure | <0.6MPa | ||
| Relay | Two-way high and low potential/one-way time relay | Thread | Triclamp、1/2NPT、3/4NPT | ||
| Installation Size | 138*138mm | Installation Method | Submerged, flow cell, pipeline | ||
| Installation Method | Panel Mounted/Wall Mounted | Cable length | 5 meters standard (support customized length) | ||
| Data Storage | 1000 pieces | ||||
| IP Grade | IP65 | ||||
Measurement Parameters: Silicate, Phosphate, Sodium, Hydrazine
| Name | Silicate Analyzer | Phosphate Analyzer | Sodium Analyzer | Hydrazine Analyzer |
| Model | GSGG-5089Pro | LSGG-5090Pro | DWG-5088Pro | LNG-5087Pro |
| Measuring Range | 0-200/2000μg/L(Customize) | 0-20/50mg/L(Customize) | 0-100μg/L | 0-100μg/L |
| Accuracy | ±2%F.S.or 2ug/L | ±1%FS | ±2.5%F.S.pH±0.1 | ±1%F.S. |
| Repeatability | ±1%F.S. | ±2.5% | ±1%F.S. | |
| Stability | Drift<±1% F.S./24 hour | ±2.5%/24h | Drift <±1% F.S. / 24 hours | |
| Sampling period | 10mins/channel | 5mins/channel | Instant | 6mins/channel |
| Water sample | Flow rate: >50 mL/ min ; Temperaure : 10-45℃ Pressure : 10-100kPa | Flow: >100 mL/ min; Temperature: 0-60℃; Pressure: < 0.6 MPa | Flow: >100 mlL/ min; Temperature: 10-45℃; Pressure: 10-100kPa | |
| Relay | 220V/1A | 220V/1A | 220V/1A | |
| Output | RS485;4-20mA | 4-20mA/0-10mA;RS485 | 4-20mA;RS485 | |
| Power supply | AC 220V±10% 50Hz | AC220V±10% 50Hz | ||
| Dimention | 710 • 450 • 310mm (H • W • D) | 710 • 450 • 310mm (H•W•D) | ||
| Hole size | 667 • 407mm | 667 • 407mm | ||
| Working condition | Temperature : 5-50℃; Relative humidity: < 85% RH | Temperature : 5-50℃; Relative humidity: < 85% RH | ||