Leave Your Message
Steam Water Analysis System(SWAS)
Application
Application Categories
Featured Application

Steam Water Analysis System(SWAS)

2026-09-23

Steam Water Analysis System

A Steam Water Analysis System (SWAS) is an integrated online monitoring system designed to continuously analyze the quality of steam, boiler water, feedwater, condensate, and other water-steam cycle streams in industrial steam and power-generation systems. By continuously monitoring key water quality parameters such as pH, conductivity, dissolved oxygen, silica, sodium, phosphate, and chloride, a SWAS helps operators detect contamination, corrosion, scaling, and other potential problems at an early stage.

In a typical SWAS, water or steam samples are extracted from different points in the process and then conditioned through cooling, pressure reduction, filtration, and flow control before entering online analyzers. The measurement data can be transmitted to a DCS, PLC, SCADA, or plant control system, enabling real-time monitoring, alarm management, and process optimization.

Maintaining proper water and steam chemistry is critical because impurities in the water-steam cycle can cause boiler scaling, corrosion, turbine deposits, reduced heat-transfer efficiency, and equipment damage. A well-designed SWAS therefore plays an important role in improving equipment reliability, reducing maintenance costs, increasing energy efficiency, and extending the service life of critical equipment.

Steam Water Analysis System 2

In a thermal power plant, water goes through a continuous cycle:

Raw Water → Water Treatment → Demineralized Water → Boiler Feedwater → Boiler → Steam → Turbine → Condenser → Condensate → Feedwater

During this process, even a small amount of contamination or a change in water chemistry can create serious problems.

For example, excessive conductivity may indicate contamination. Low pH can accelerate corrosion, while excessive dissolved oxygen can promote oxygen corrosion. Silica can be carried into steam and deposited on turbine blades, reducing turbine efficiency.

Therefore, the purpose of SWAS is not simply to "measure water quality." It is to provide continuous monitoring of critical chemical parameters throughout the water-steam cycle, allowing operators to identify abnormal conditions at an early stage.

The selection of water quality analyzers is one of the most important steps when designing a SWAS.

It is not enough to simply choose an analyzer according to the parameter that needs to be measured.

The sampling conditions and process requirements must also be considered.This means the analyzer configuration should be customized according to the monitoring objective rather than using the same analyzer combination at every sampling point.

As an experienced manufacturer of water quality monitoring equipment, Shanghai Boqu Instrument Co., Ltd. develops and supplies a range of water quality analyzers and water quality sensors that can be applied to industrial water monitoring and SWAS-related applications.

Its product portfolio covers multiple analytical parameters, including pH, conductivity, dissolved oxygen, turbidity, residual chlorine, and other water quality indicators, providing flexible options for different industrial monitoring requirements.

For SWAS applications, the analyzer and sensor should be selected according to the specific sampling point and process conditions. For example, a power plant may require different measurement configurations for feedwater, condensate, boiler water, demineralized water, and cooling water.

The use of suitable online analyzers and sensors enables continuous measurement and reduces dependence on intermittent laboratory sampling. Combined with an appropriate sampling and conditioning system, these instruments can become an important part of a plant's overall water chemistry monitoring strategy.

For system integrators and power plant operators, this also makes it possible to develop a modular SWAS solution based on the actual process requirements rather than adopting a one-size-fits-all configuration.

‌Schematic Diagram of Water Quality Monitoring Process in Thermal Power Plants

‌Schematic Diagram of Water Quality Monitoring Process in Thermal Power Plants

Recommended Water Analyzer

‌Measurement Parameter: pH

Model PHG-2081Pro Model PH-8022 CPH-800 ORP-8083A
Measuring Range -2-16pH Measuring Range 0-14 pH ±1900mV
Accuracy ±0.05 pH Accuracy ±0.05pH ±20mV
Working Temperature -20-50 ℃ Applicable Compensation NTC10K,NTC2.252K,Pt1000
Output One RS485, Two 4-20mA Applicable Temperature 0-60 ℃
Relay Two high and low relay /One time relay Pressure range Atmospheric Pressure <0.6 MPa
Power Supply 90V – 260V AC 50/60Hz (24V alternative) Connector Low-noise Cable Goes Out Directly
Installation Size 138*138mm Connection Thread Upper and Lower 3/4NPT PG13.5 PG13.5
Installation Panel/Wall Installation Main Material PC Glass (Sand Core Penetration) Glass (Tetrafluoride Permeation)
Data Storage 1000 Groups Installation Flow-through/Pipe Installation Flow-through Flow-through
Waterproof Class IP65 Cable Length 5m (Customizable)

Recommended Products

‌Measurement Parameter: Dissolved Oxygen

Model DOG-2082Pro DOG-2082Pro-L Model DOG-208F DOG-208F-L(Suitable for DOG-2082PRO-L)
Range 0~20mg/L 0~20mg/L,0-100ug/L Range 0-200ug/L 0-100ug/L
Accuracy ±1%F.S. <±1.5%F.S. or 1µg/L(Take the larger one) Accuracy ±0.1ug/L <±1.5%F.S or 1µg/L(whichever is greater)
Working Temperature 0~60℃ 0-50℃ Temperature Compensation NTC2.252K, NTC22K, Ptl00, Ptl000 30K
Output One-way RS485,two-way 4-20mA Measure Temperature 0-50℃ 0-50℃
Relay Two high and low relay /One time relay Pressure Atmospheric pressure <1mpa
Power 100~240V (24V alternative) Material SS316L POM
Installation Size 138*138mm Cable Length 5m or 10m(Double shielding) -
Installation Method Panel/Wall Installation Flow-through Flow-through
Storage 1000 times
Protection Grade IP65

Recommended Products

‌Measurement Parameter: Conductivity/TDS/Salinity/Resistivity

Model No DDG-2080Pro Model No DDG-0.01 DDG-0.1 DDG-1.0
Measure Range Conductivity: 0-2000000 uS/ cm (0 ~2000 mS/cm); TDS: 0-130000 mg/L(ppm); Salinity: 0-80 g/L(ppt); Resistivity: 0-20 MΩ•cm; Temp: -40-200 ℃. (Measure range depends on related sensor) Measuring Range K=0.01 0-20μS/cm K=0.1 0-200μS/cm K=1.0 0-2000μS/cm
Accuracy ±2% ;±0.5℃ Accuracy ±2% FS
Working Temerature 0-60℃ Temp compensation Pt1000,NTC10K,NTC2.252K
Communication Modbus RTU Working Temp 0-60℃
Signal Output One-way RS485,two-way 4-20mA Electrode Material Stainless steel, titanium alloy, platinum
Powwer supply 90V – 260V AC 50/60Hz (24V alternative) Pressure <0.6MPa
Relay Two-way high and low potential/one-way time relay Thread Triclamp、1/2NPT、3/4NPT
Installation Size 138*138mm Installation Method Submerged, flow cell, pipeline
Installation Method Panel Mounted/Wall Mounted Cable length 5 meters standard (support customized length)
Data Storage 1000 pieces
IP Grade IP65

Recommended Products

‌Measurement Parameters: Silicate, Phosphate, Sodium, Hydrazine

Name Silicate Analyzer Phosphate Analyzer Sodium Analyzer Hydrazine Analyzer
Model GSGG-5089Pro LSGG-5090Pro DWG-5088Pro LNG-5087Pro
Measuring Range 0-200/2000μg/L(Customize) 0-20/50mg/L(Customize) 0-100μg/L 0-100μg/L
Accuracy ±2%F.S.or 2ug/L ±1%FS ±2.5%F.S.pH±0.1 ±1%F.S.
Repeatability ±1%F.S. ±2.5% ±1%F.S.
Stability Drift<±1% F.S./24 hour ±2.5%/24h Drift <±1% F.S. / 24 hours
Sampling period 10mins/channel 5mins/channel Instant 6mins/channel
Water sample Flow rate: >50 mL/ min ; Temperaure : 10-45℃ Pressure : 10-100kPa Flow: >100 mL/ min; Temperature: 0-60℃; Pressure: < 0.6 MPa Flow: >100 mlL/ min; Temperature: 10-45℃; Pressure: 10-100kPa
Relay 220V/1A 220V/1A 220V/1A
Output RS485;4-20mA 4-20mA/0-10mA;RS485 4-20mA;RS485
Power supply AC 220V±10% 50Hz AC220V±10% 50Hz
Dimention 710 • 450 • 310mm (H • W • D) 710 • 450 • 310mm (H•W•D)
Hole size 667 • 407mm 667 • 407mm
Working condition Temperature : 5-50℃; Relative humidity: < 85% RH Temperature : 5-50℃; Relative humidity: < 85% RH