Drinking Water Plant

Safe and reliable drinking water is essential to public health. A drinking water treatment plant must continuously control water quality from raw water intake to treatment, disinfection, and final distribution. Because water quality can change rapidly due to rainfall, seasonal variations, source-water pollution, chemical dosing, filtration performance, and equipment conditions, real-time online water quality monitoring has become an important part of modern drinking water treatment.
The World Health Organization (WHO) recommends operational monitoring of parameters such as turbidity, pH, disinfectant residual, conductivity, and other process indicators to verify that treatment barriers are working effectively. Online monitoring allows operators to detect abnormal changes quickly and adjust coagulation, filtration, chemical dosing, or disinfection processes before water quality problems reach consumers.
Shanghai BOQU Instrument Co., Ltd. provides online water quality analyzers and sensors for drinking water treatment plants, municipal water supply systems, and secondary water supply applications. Its solutions can be configured according to different treatment processes and monitoring requirements.By combining reliable sensors, online analyzers, data transmission, alarms, and customized parameter configurations, Shanghai BOQU Instrument Co., Ltd. helps drinking water plants achieve continuous, automated, and data-driven water quality management—from raw water intake to the final drinking water supply.

Recommended Solutions from Boqu Instrument
| Parameters | Model | Measurement Range |
| pH | pH2081Pro Online pH Meter | -2-16pH |
| Turbidity | TBG-2088S/P Online Turbidity Meter | 0-20 NTU, 0-200 NTU |
| Suspended soild(TSS) | TSG-2087S Industrial Total Suspended Solids (TSS) Meter | 0-99999mg/L |
| Conductivity | DDG-2080Pro Online Conductivity Meter | 0-2000000uS/cm (0-2000mS/cm) |
| Dissolved Oxygen | DOG-2082Pro Online Dissolved Oxygen Meter | 0-20mg/L |
| Residual chlorine | CLG-2059S/P Online Residual Chlorine Meter | 0-2mg/L (pH:5.5-10.5) |
| Hardness (Ca2+) | PXG-2085Pro Online Ion Meter(Ca2+) | 0.0ppm-99999ppm |
| Level | BQ-ULM Ultrasonic Level Meter | |
| Flow | BQ-MAG Electromagnetic flow meter | |
| pH, Turbidity, Conductivity, Residual chlorine, Temperature | DCSG-2099Pro Multi-parameter Water Quality Meter |
Measurement Parameter: Conductivity/TDS/Salinity/Resistivity
Model No |
DCSG-2099Pro |
Measuring Parameters |
pH/ Residual chlorine/ Conductivity/ Turbidity/ Temp (other parameters can be customized) |
Measuring Range |
pH:0-14pH |
Conductivity:0-2000µS/cm | |
Residual chlorine:0-2mg/L | |
Turbidity:0-20/200NTU(90°scattered light ) | |
Temp:0-60°C | |
Resolution |
pH:0.01pH |
Conductivity:1µS/cm | |
Residual chlorine: 0.01mg | |
Turbidity:0.01NTU | |
Temp:0.1℃ | |
Accuracy |
pH:±0.1pH |
Conductivity: ±1%FS | |
Residual Chlorine:±2%FS | |
Turbidity:±2% | |
Temp:±0.5℃ | |
Communication |
RS485,4-20mA ( optional) |
Power Supply |
AC 220V±10% |
Working condition |
Temp: 0-50℃; |
Inlet/Outlet pipe diameter |
6mm/16mm |
Inlet water flow |
200-500mL/min |